If the shaft is free turning but it makes a hum or buzz sound, usually followed by a tripping breaker, check the capacitor, it may have failed. Hi David, yes! Filter or pump baskets are dirty. Otherwise, it can be loose or corroded connections on the 3 wires that connect the motor to the drive. Inspect the following areas: If you see air bubbles coming from the return fittings on the pump, there may be an air leak on the suction side. Essentially, its probably something loose/broken, or a bad capacitor, which is like the battery to help it get up to high speed. Specialties: Cycling, Kickboxing, The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Third, is that breakers sometimes dont last forever, and can be go bad, usually after 20-30 yrs tho. In most cases, no worries that it will blow-out to leave a leaking pump running. I have a new above ground pool with a Hayword pump. The motor had stopped when I checked in morning. I just got my home back, I walked outside and pool level was well below jets. Thanks for the help. Once we turn the pump on it runs good for a couple of mins then then once it builds up pressure the water pressure into the pool slowly stops. Holding the shaft stationary (so it wont turn), unthread the impeller, counter clockwise, to remove. Use the [7/16] wrench to wiggle the shaft through several revolutionsto free up the shaft. Have no power at all going to my control panel. https://www.facebook.com/inyopoolsFOLLOW us on TWITTER! Automatic reset is 60 minutes. Hi John, do you mean the filter top pops off? Does anyone know how to reset an sf error code after a new thermistor has been installed? Air can also enter through split vac hoses, but since yours is new Third problem could be if the new pump moves much more water than the old pump (not all horsepower pumps are the same 2 different pumps of the same hp, can produce vastly different flow rates. Or a loose base part rattling? Please advise. If they are within range, replace drive. I have an above ground 18,000gal poola Hayward SP1580X15 Power-Flo LX 1 1/2 HP pump purchased May 2017. The outer walls become thin, allowing the pipe to crimp but only under high vacuum pressure, otherwise seems normal. The process, for changing a hayward pump seal is: 1. I would think that going to 1 hp superpump, from a 1.5 hp superpump, would not be a problem. When I (electrician) arrived I was able to measure 38volts to ground in the water when the main pump (Hayward Tristar) is running. Almost ordered a new pump but it really sounded good. It will start to run normal for 2-3 seconds. Hello , This is an inactive thread. We are out of ideas and no one can solve this. We replaced fhe shaft seal but the pump doesnt pull any water in there is no suction. Hayward should be able to help, http://www.haywardnet.com see for contact info. I used electrical tape so the impeller HELP! Hi, I have a filter timer and a cleaner timer that are side-by-side. It worked fine just prior to a filter cleaning. When they fail, they often crack, bulge, leak or smell bad, but not always. Look closely at the suction-side (incoming pipes/valves, up to the strainer pot), and shut off pump, watching closely for water spray, or sometimes just a fast dribble. Turned it off tho clear the skimmer basket.. water level is correct. It was off this morning and I reset the breaker. Appreciate any help. I have opened a pool and I have kept pump running 24 hrs due to Alge but few hours later there is no water moving in pool. No leaks, pressure is good, suction is good, connections seem right. The filter is clean. The shaft turned with zero resistance. What can we check. Is the wire the correct size wire? "height": "219",
Do you have to find the pump up with water before turning it on? I have 2 pumps, Ecostar for pool and Tristar VS for my waterfall, the pool pump is working fine, the Tristar will not come on, when I use my Omnilogic app or or the panel to turn on it just says-paused/valve change, but there is no valve change going on-having a Memorial Day party this Saturday and getting a bit freaked out, I have tried calling support, but they put me on indefinite hold, and I cant seem to get in touch with pool company-please help. Well the electrician said it was a bad motor and to contact hayward to replace. The o-ring should be a very tight fit also, not loose in the groove of the lid. Let it sit overnight . Hi Joe, I would first suspect an air leak, Superpumps can also draw air from a loose drain plug and easily around the square lid gasket but the usual suspect is the pipe coming into the pump. Theory and practice | Find, read and cite all the research you need on ResearchGate Fitness View More. This is more of an indicator light than anything else. Hi Chris, is the vacuum hose fully primed with water before you attach it to the skimmer, you say primed and ready to go, so I assume so. The stickers and labels mean it is WIRED to allow for 230. With a test meter, you check power at the motor, and it should be within 10% of 120V or 240V, whichever the motor is wired for, and if not, the power is traced back to a point where it full power is found, on the meter. Pump lid not on tight enough Pump Surging also occurs from low water level, or air leaks in front of the pump. I will be purchasing a replacement pump and have it installed, but I wonder if Id need to just have the breakers tightened in the panel box? Reprime the pump again, open water valves and test. If none of those things, perhaps the filter grid needs to be soaked in a Filter Cleaner, to remove oils or minerals that have clogged the pores of the fabric. if it does not come back on, check switches, turn breaker all the way off and back on again. My prior one was over 12 years old so Im feeling uncertain. Water began flowing out the pump motor and it tripped the gfci. 12 ga or 14 ga? Hi Larry, When DE is coming back into the pool, its usually: IF the shaft spins freely, and your motor hums and trips the breaker, first check the wiring connections on the incoming wires, nice and tight, and no bare wire touching anything except the terminal connector. Sometimes it is just a stick or debris stuck between the valve diverter (aka rotor or footpad) and the spider gasket, and a little wiggle or jiggle or repositioning of the handle can seal up the waste port, for a time If it reoccurs, this means that the spider gasket is twisted, worn or damaged. Now if its not an air leak, surging can also be caused by a clog in the pipe, usually a solid object like a golf ball, getting sucked back and forth in the pipe. Hi Bryan, not normal but not uncommon. Hi Amy, the timer is usually wired between the pump and the breaker. Now if none of that advice helps, and you still cannot get the lid to go on, or seal up, I would suspect that either the lid or the housing is warped from an overheating situation, running for long periods of time without water flowing through it. When I turned off the pump I saw that it spit a little bit of water out of a Jandy Valve. Did you figure out your problem? It could be air in the pump, or it could be that the pump is too big (powerful) for the number of pipes. Please help! },
"@type": "ImageObject",
My Hayward h250 propane heater keeps blowing fc1 and fc2 fuses immediately after plugging in. I dont think it ran dry, if the pump outlet hose came loose (not the inlet?). Thanks. If the problem continues after fixing the problems above, you may have a clog in the suction side of your pump. It's the same as an aquarite with a T-5 cell. But just like any sort of equipment, even the most well-made products sometimes need repairs. "logo": {
If you are running the pump at full steam, and then shut it off, while looking very closely at these areas, you may see a quick spurt of water, which is where the air leak is originating from. I believe I checked everything and hoping its just the electric cord and the fact that it is corroded and loose and likely loosing electric current after it gets heated up a bit. That motor is sometimes used on the Hayward Superpump which is the only pump with a SQUARE pump basket. our previous pump was a hayward variable. Manually spinning the shaft can break the rust bonds. Grass clippings, seeds, gravel or other small debris can clog an impeller and reduce suction. Hi Matt, my first guess would be an air leak on the suction side, most typically a loose pump lid (or no o-ring lube), or loose pipe that comes into the front of the pump (or no thread sealant on the threaded fitting), or sometimes a leaky suction side valve, or low water level, stuck skimmer weir Second guess would be a broken impeller, detached from the motor shaft. My guess is they would pronounce it DOA, but may find something interesting, or may find no problem at all, which would lead you to suspect the wiring, breaker, timer the source of power. Now assuming your pressure gauge is accurate, 20 psi would tell me that your filter grid fingers need a serious cleaning. Is this rare? Upon reading alot of articles and watching videos, it seems the pump came with the clamp on the 115V setting? Theory and practice | Find, read and cite all the research you need on ResearchGate Chapter 1: The Evil Emperor's Son. It may not display this or other websites correctly. Heaters often normally make such sounds, could also be debris laying on top of the burners. Thanks. There can be multiple reasons for a pool pump not priming correctly. Anyway, have you checked the cleaner line strainer? Any ideas how to address this? }
. If it is not, re-align your flow switch. Not sure if this is somehow related to the water being heated or maybe air in the pump just guesses. Hi Curt, not especially uncommon, small stress cracks on the outlet port of the pump, about 1/4 long? main drain and skimmer) to feed this thirsty pump. Find answers to your questions about all It is a common problem with Hayward Perflex, the symptoms you describe, and is usually clogged fingers. Thats unusual, shouldve fixed it. If so, put a damper under the pump, a piece of heavy rubber or a shim to stabilize the pump. There is water, not a lot, but water at the base of the pump. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. During that time, the pump got really hot and melted the fitting on the top. Hi Wilson, I cant find any info on that error message paused / valve change but it would sound like it thinks that either a filter valve or directional valve is being turned, so it has paused water flow. And since it was running before (it shut off), its probably not rust. Also will need to have clean pump basket and a clean pool filter, to ensure adequate flow rates. how to watch past broadcasts on twitch. I have taken it apart and put it back together probably 5-6 times looking for internal issues. Any ideas? If the No Flow LED is flashing, wait 60 seconds after starting your pump and filter. Not sure if I need to purchase a new pump. If it still wont catch full prime, open up the pump so you can ream out the impeller vanes with wire or a skinny screwdriver. Any ideas on what may be going on? Hi you are getting power inside the motor, on the terminal board? It could also be a clogged impeller or clogged filter, or clogged skimmer line. Ours is doing the same thing. Same with other sensors. In most cases, its going to be #1, just a frozen motor as we say If the shaft spins freely, and it makes a hum or buzz sound for a few seconds before it trips the breaker, probably #4. $5.99 $3.99 As low as $1.79 WFO RS-23-SED Sediment Water Prefilter Compatible With Culligan S7011C & 00-4015-38 AquaCleer Good Water Machine $16.99 $9.99 As low as $7.99 Our pump is going through this one-off cycle similar to what others are describing. What am I not doing? Hi there, I made the very unfortunate decision to rent my home to a friend. Is this normal? If that all checks out, be sure that there are no air leaks on the suction side of the impeller, around the lid, drain plugs or pipe coming into pump. 3. slide pump backwards, out of the housing, remove diffuser and wear ring from impeller Inspect wiring for any loose or corroded connections. A less common cause of water out of the waste line is a broken Spring, under the handle, indicated by a floppy handle or difficulty turning the valve, I have a Hayward Super Pump it will run for about 1 to 2 hours and then it shuts off once it cools off for an hour or so I can turn it back on it will run again the water flow its good its just shuts off when it gets hot, Hi Steve; check that you have good air flow all around the pump, and above. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have 25 The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. For the clamp band, yes the washer with the slightly smaller hole I.D. Hi Clara click doesnt sound like a motor runnning, perhaps you are hearing a relay click, but if the motor itself is not turning over there could be a multitude of reasons why, but in most of these cases, the problem lies where the power dies. "@type": "ImageObject",
Not sure if Hayward will cover, but if you have your original purchase invoice, check the warranty for your pump, should be able to find on haywardnet.com to see if bearings are excluded, or to check the warranty period. I did notice the on/off switch was mushy moving from the on and off positions. Not that I can think of, but something seems to be aerating your water? If you have a filter pressure gauge, the practice is to clean the filter when the pressure gauge rises 7-9 psi above the clean, starting pressure. Hi Davy. You should be able to lift up on the pump just slightly, to push something thin, 1/4 thick or less, beneath it. Replace the seal in the same orientation as you removed it, and reassemble. dr myers ultrasound. You can also order capacitors online. Switch your cell type by cycling the main switch from AUTO to SUPER CHLORINATE and then back to AUTO. Breaker for the pump is not tripped. Use a Drain King to pressurize the pipe backwards, to remove such clogs. PUMP IS 15 YEARS OLD. If voltage is normal, there may be a loose wire in the motor, perhaps behind the terminal board, or a bent wire that is touching some metal housing, or bent and touching another wire. The trick is the little plug on the electrical panel MUST be moved to either 230 (up one) or to 115 (down). Click here to shop our store. I took apart the impeller and didnt see anything that could cause a problem. Hi Chris, the first thing I would check, since the motor is making no noise at all (? What do you suggest? Tonight, I tried to manually start the filter and all I hear is a click in the mother board. last year, I replaced the Sand & O ring on the filter, and I resealed the O ring on both the filter & Pump with O ring lube. Examine your pumps impeller for any obstructions, and replace the capacitor if necessary. In my experience, a motor overheating is usually on its last legs what you could do is take it to an electric motor shop in town, and have them run it thru some diagnostics, should not be too expensive, but call first to check. If still nothing, look for damage in the rear of the motor, something burned, melted, loose, or pinched or cut wires. Not all horsepowers are created equal, meaning that a 1hp Hayward Super II pumps a lot more water than a 1hp Hayward Super I, or Max-Flo. Hi Steven, probably the breaker tripped or the GFCI test button popped out due to some water touching some wire. dont know if the pump went bad already. But higher pressure and no suction, that means an obstruction PAST the impeller. Hi, like some of the other comments, when a pump basket doesnt fully fill with water, doesnt fully catch prime the first thing is to rule out an Air Leak, on the suction side. I purchased it June of 2018. When I tighten the impeller onto to the motor how tight should it be? (I just bought the house and am new to pool upkeep.). I would inspect it for corrosion, wire tightness, water damage or insect damage. By following the steps listed below, the Aqua Rite can successfully be restored.To view this guide step by step on our website, visit:http://www.inyopools.com/HowToPage/how_to_troubleshoot_a_hayward_aqua_rite.aspx Can I replace this pump housing or do I need a new pump? If it is cycling on/off (motor turning on/off) more rapidly, that would usually indicate loose wires, loose breaker, broken wires (sometimes inside the flexible conduit). Thank you so much for taking time to answer all our concerns. Calling the pool builder for warranty info, too. Tighten the fitting hand tight, plus 1/2 turn or so, until really snug, but not super-tight. First, I want to ensure the pool is voltage free, thus grounded and all components are bonded, I know many pumps have a zinc plate that actually bonds the water. Diagnosing and Troubleshooting Your Hayward Aqua Rite System - INYOPools I did the shaving cream trick and no air leak detected. I changed the sand and it is still occurring. You can experiment with pump RPM settings, to exceed the threshold. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. What is the problem. You find these in our valve parts department or use one of our multiport valve rebuild kits. Any ideas on how to fix this issue?? Ran it for two hours, then shut it down to move valve to backwash. Open faced impellers need very large pliers, or a strap wrench, some have special tools to remove open brass impellers. If from the center of the lid around the stem, you can replace the two small stem o-rings, but sometimes the stem is worn down and needs replacement. Checked circuit breakers inside and out and checked to make sure power is getting to pump. Then dunk them in the pool quickly after the acid, to rinse cleanly. Inspect and clean your cell. "identifier": ""
We are a registered 501(c)3 non-profit that is funded by user donations. Hi David, spilling water on the motor is no problem, they do fine outside in the rain (flooding is a different story) Have you checked the GFCI test button on the outlet? then I tried to switch it on again but the pump wont start. Hi, I changed my Sta Rite motor, it was 10 years old and did not start anylonger, with a brand new one. If you have a multiport valve, set it on Recirculate, to bypass the filter, and rule out any problems there. Stackable Rose Gold Wedding Bands,